SensoControl Service Master Plus | Parker K-SCM-500-01-01-ENG

Service Master Plus - Digital Diagnostic Meter | Part # K-SCM-500-01-01-ENG


The Parker Service Master Plus is a premiere portable diagnostic tool. It incorporates data measurement, display, and on-screen analysis in one package.

The Service Master Plus meters can be purchased individually or in kits. For Service Master Plus kit, please see the bottom of this page. Other SensoControl meters and gauges are available, please go to SensoControl Meter Selection to compare different SensoControl meters.

 

  SensoControl Service Master Plus Digital Meter

User Manuals:

  • Service Master Plus User Manual

  • Service Master Plus Instrucciónes para el manejo

  • Service Master Plus Bedienungsanleitung

  • Service Master Plus Mode d'emploi

  • Service Master Plus Gebruiksaanwijzing

  • Service Master Plus Istruzioni per l'uso

Capabilities:

  • Hand held diagnostic meter

Measure and Display:

  • Pressure
  • Flow
  • RPM (rotations per minute)
  • Temperature
  • Auxiliary Inputs

Features:

  • 26 Sensor Inputs
  • Auto Sensor Recognition
  • CAN open sensors
  • Full Color Data Display
  • SensoWin Software Utility
  • Store Data on the Device, PC or micro SD Card
  • Rugged Design
  • 1-ms Scan Rate
  • Configurable as FASAT-mode analog inputs - 0.1-ms Scan Rate

 

Connection Diagram | Service Master Plus K-SCM-500-01-01-ENG

Service Master Plus Diagram

Key Description Part Number
1 CAN Connection Cable (2M, 5M & 10M) SCK-401-02-4F-4M
SCK-401-05-4F-4M
SCK-401-10-4F-4M
2 Analog Connection Cable (3M) SCK-102-03-02
3 CAN Y-Junction SCK-401-0.3-Y
4 CAN Terminating Resistor SCK-401-R
5 CAN Pressure/Temperature Sensor PDXXXXX-XXXX-CAN
6 Analog Pressure/Temperature Sensor PDXXXXX-XXXX
7 Analog Flow Sensor SCFT-XXXX-XXX
8 Analog Temperature Sensor SCT-150-04-02
9 Service Master Plus Instrument K-SCM-500-01-01-ENG
- CAN Flow Sensor SCFT-XXXX-XXX-CAN

 

 

SensoControl Service Master Plus Kit

 SensoControl Service Master Plus Kit

Service Master Plus Kit Contents

  • Case (SCC-500-ENG)
  • Service Master Plus meter (K-SCM-500-01-01-ENG)
  • 2 Transducers (see below)
  • 2 Cables, 5 m (see below)
  • Power Supply (SCSN-460)
  • SensoWin Software 6.0 (SC-CD 4082)
  • USB PC Cable (SCK-318-02-35)
  • SensoWin Software
  • Instructions Manual
  • CAT 5 LAN Cable

Code for Ordering Service Master Plus Kits

PDSMP-50-C-TT-TT-XXX

  • C - Coupling style:
    • 2 = PD style
    • 6 = EMA 3 style (female)
  • TT - Transducer pressure range (psi)
    (Order either one or two)
    • 01 = -14.5 - +235 (Blue)
    • 06 = 0 - 870 (Green)
    • 15 = 0 - 2175 (Yellow)
    • 40 = 0 - 5800 (Orange)
    • 60 = 0 - 8700 (Red)
  • XXX - Technology
    • CAN = CAN Bus
    • Leave blank for Analog

 



SensoControl Service Master Plus Support

 

Hose & Fittings, Etc. supports its customers during and after the purchase of SensoControl Service Master meters. Our in-house expert is available to train your mechanics at your location (anywhere in Northern California and North-Western Nevada). If you prefer, training can also be arranged in Hose & Fitting, Etc’s West Sacramento headquarters.

 
Ask Question
 
Request a Quote

Questions?


Ask Question

Request a Quote


TECHNICAL DATA
Service Master Plus
K-SCM-500-01-01-ENG

FUNCTIONS

  • Measures actual, Min, and Max quantities
  • Displays numerical values, bar graph, pointer, and curve graph (function)
  • Remote operation via Ethernet
  • Acustic event notifications
  • Displays: pressure, temperature, flow and rotational speed
    • Pressure - PSI and Bar
    • Temp. - °F and °C
    • Flow - GPM and l/min
    • Speed - RPM
  • Differential Value Mesaurement
  • Min/Max Memory
  • Online Data Transfer
  • Batery Level Indicator
  • Auto Power-Off
  • Color Display
    • 115 x 86 mm Screen
    • 640 x 480 px

INPUT/OUTPUT

  • 2 CANbus Networks with 8 Inputs Each (16 Total)
  • 6 Senso Control Sensor Inputs
  • Parker Automatic Sensor Recognitioin
  • 5-Pin Push-Pull Connections
  • 2 Auxiliary Analog Inputs for Measuring Current
    and Voltage
  • Configurable as FAST-Mode Analog Inputs (0.1 ms Scanning Rate)
  • Digital Active High I/O 7 to 24 V (DC)
  • Digital Active Low I/O < 1 V (DC)
  • Input Impendance - 1 k-Ohm
  • Output Current - 20 mA

MEMORY

  • Internal - 64 MB
  • External Micro SD Slot
  • External USB Mass STorage Slot
  • 6 Million Data Points per Measurement
  • 1 Billion Data Points Total Storage

POWER

  • Internal Lithium-Ion Pack
  • External 110V/240V AC
  • 8-Hour Battery Life
  • 3-Hour Charge Time

AMBIENT CONDITIONS

  • Operating Temperature 32°F - 112°F
  • Storing Temperature -10°F - 140°F
  • Relative Humidity < 80%

HOUSING

  • ABS/PC (Thermoplastic) Casing
  • Housing Protective Sleeve Material: TPE (Thermoplastic Elastomer)
  • Protection:
    • IEC60068-2-32, (1 m Free Fall)
    • IP64 (to EN60529, unconnected)
    • IP54 (connected)

DIMENSIONS

  • 257 x 181 x 75 mm
  • 3.4 lb

Related Products & Info

Senso Control METERS

Senso Control Meter Selection

Parker Service Junior

Parker Service Junior - Wireless

Parker Serviceman (Obsoleted)

Parker Serviceman Plus

Parker Service Master Easy

Parker Service Master Plus

Senso Control ACCESSORIES

Senso Control Accessory Selection

Analog Pressure Transducers

CAN Pressure Transducers

Analog Flow Sensors

CAN Flow Sensors

Adapters, Cables, Software

Test Port Couplings

 
Download Catalog