Parker | BLUE THUNDER® UHMWPE Chemical Hose | 7373T Series


Series 7373T is a high pressure, high temperature suction and discharge hose designed to handle approximately 98% of commonly used acids, chemicals and solvents. The ultra high molecular weight polyethylene (UHMWPE) tube will not leach into and contaminate the product being conveyed, and features a temperature rating to 250°F (121°C). The corrugated hose construction incorporates a dual wire helix that provides full suction capability, kink resistance, flexibility for ease of handling, and a path to conduct a static electrical charge to ground. The cover is resistant to abrasion, mild chemicals and ozone. Series 7373T is available in 200-foot continuous lengths

 

TUBE Translucent ultra high molecular weight polyethylene (UHMWPE)
REINFORCEMENT Multiple textile plies with dual wire helix
COVER Blue EPDM; corrugated wrapped finish
TEMPERATURE RANGE

-40°F to 180°F (-40°C to 82°C)

(Note: The maximum temperature for Parker's chemical hose with UHMWPE has been reduced from 250°F to 180°F. This change is effective immediately and is a safety measure to avoid misapplications with chemical hose at high temperatures.)

DESIGN FACTOR 4:1
INDUSTRY STANDARDS None applicable
APPLICATIONS
  • Acid, chemicals, solvents
  • In-plant and storage tank transfer
  • Delivery, transport
VACUUM Full
COMPARE TO Boston Chemcat; Gates Renegade; Veyance Fabchem
PACKAGING Coils




Part Number

ID

Reinf
Plies

OD

Min Bend Rad

Max Rec WP

Perm Cplg Rec

(in)

(in)

(in)

(psi)

7373T-750

3/4

2

1.193

3.0

200

43

7373T-1000

1

2

1.457

3.0

200

43

7373T-1250

1-1/4

2

1.700

4.0

200

43

7373T-1500

1-1/2

2

1.965

5.0

200

43

7373T-2000

2

2

2.560

6.0

200

43, RE, RST, TM, WC

7373T-2500

2-1/2

4

3.154

7.0

200

*

7373T-3000

3

4

3.645

7.0

200

HAPS, RE, RST, TM

7373T-4000

4

4

4.724

8.0

200

HAPS

*Couplings: Refer to CrimpSource at www.safehose.com for coupling recommendations and crimp specifications.

WARNING!

  • It is the responsibility of the user to determine if the hose is suitable for the application. Most chemical resistance guides are based on temperatures of 70°F (21°C). Elevated temperatures can change the chemical resistance ratings. Many chemicals will become more aggressive as temperatures increase, reducing the ability of hose compounds to withstand them. Contact Parker for chemical compatibility data at elevated temperatures. If no data exists, users are required to perform compatibility testing at the desired temperature.
  • At operating temperatures of 125°F and above, only permanently attached couplings should be installed. At any operating temperature, couplings attached with bands or clamps may reduce the working pressure of the hose assembly to less than the maximum rated working pressure of the hose. Refer to the NAHAD Industrial Hose Assembly Guidelines.
  • „Do not use with internally expanded couplings. Refer to chemical hoses that incorporate a MXLPE tube.

 

 

How to Order