Chemical Industrial Hoses | Parker | POLY-CHEM® XLPE Chemical Hose | 7276 Series


 

Series 7276 is a suction and discharge hose designed to handle many commonly used acids, chemicals and solvents. The cross-linked polyethylene (XLPE) tube will not leach into and contaminate the product being conveyed. The hose construction incorporates a wire helix that provides full suction capability, kink resistance and a path to conduct a static electrical charge to ground. The cover is resistant to abrasion, mild chemicals and ozone. Series 7276 is available in 200-foot continuous lengths.

 

TUBE Translucent cross-linked polyethylene (XLPE)
REINFORCEMENT Multiple textile plies with dual wire helix
COVER Green EPDM; wrapped finish
TEMPERATURE RANGE

-20°F to 160°F (-29°C to 71°C)

DESIGN FACTOR 4:1
INDUSTRY STANDARDS None applicable
APPLICATIONS
  • Acids, chemicals, solvents
  • In-plant tank transfer
  • Delivery, transport
VACUUM Full
COMPARE TO Boston Panther Chemical Transfer; Veyance Blue Flexwing
PACKAGING Coils



Part Number

ID

Reinf

OD

Min Bend Rad

Max Rec WP

Perm Cplg Rec

in

Plies

in

in

psi

7276-752

3/4

2

1.250

3.0

200

43

7276-1002

1

2

1.475

4.0

200

43

7276-1252

1-1/4

2

1.715

5.0

200

43

7276-1502

1-1/2

2

2.000

6.0

200

43

7276-2002

2

2

2.567

8.0

200

43, HAPS, RE, RST, TM, WC

7276-3002

3

4

3.606

12.0

200

RE, RST, TM

7276-4002

4

4

4.700

16.0

200

*

*Couplings: Refer to CrimpSource at www.safehose.com for coupling recommendations and crimp specifications.

WARNING!

  • It is the responsibility of the user to determine if the hose is suitable for the application. Most chemical resistance guides are based on temperatures of 70°F (21°C). Elevated temperatures can change the chemical resistance ratings. Many chemicals will become more aggressive as temperatures increase, reducing the ability of hose compounds to withstand them. Contact Parker for chemical compatibility data at elevated temperatures. If no data exists, users are required to perform compatibility testing at the desired temperature.
  • At operating temperatures of 125°F and above, only permanently attached couplings should be installed. At any operating temperature, couplings attached with bands or clamps may reduce the working pressure of the hose assembly to less than the maximum rated working pressure of the hose. Refer to the NAHAD Industrial Hose Assembly Guidelines.
  • „Do not use with internally expanded couplings. Refer to chemical hoses that incorporate a MXLPE tube.

 

How to Order